220-SEATER FLAGSHIP RESTAURANT FOR SCOTLAND’S CAPITAL
• Unusually short contract schedule
• Restricted void space
• Strict noise & odour control criteria
• PERFORMANCE
• PRESTIGE
• ENVIRONMENTAL
![]()

To meet client expectations of completion within the ambitious timeline.
To design, manufacture and construct a bespoke Exposed Kitchen Canopy allied to a hybrid DW172 / fire resisting ductwork system which would be viewable from every part of the restaurant, including the mezzanine balcony.
To meet all environmental criteria in mitigation of local planning covenants regarding odour and noise control.

To meet the demanding site schedule, which was short for even a ‘regular’ design & install layout let alone something special.
To incorporate an exposed commercial kitchen canopy, plant, ductwork and access walkway into the limited void space. The complete bespoke design not only needed to perform and be accessible for cleaning but it also had to look the part from any angle.
To devise methods to satisfy the very strict noise and odour control requirements which were essential to the brief. The environmental considerations for this central, densely-populated location were compounded by the proximity of penthouse flats to the kitchen extract discharge.

We designed, manufactured, installed and commissioned the complete HVAC system for this high-profile Wagamama restaurant project.
All HVAC services were designed using the latest 3D software and state-of-the-art modelling techniques prior to manufacture.
CANOPY & DUCTWORK
As the exposed Kitchen Canopy and ductwork were to be a key interior design feature of the restaurant, it needed to be completely bespoke.
Starting with all necessary standard features, such as induction air supply, make-up air through perforated panels along the front of the canopy and baffle filters on the kitchen exhaust, the design was then enhanced to achieve the brief.
The final kitchen ventilation / extract system incorporated a bespoke Caswell commercial kitchen canopy, odour control measures (see below), fan, medium-pressure ductwork to BESA Specifications DW172 & DW142, duct attenuators and a short 10m run of CASWELL FIRESAFE® fire resisting ductwork to bridge the escape corridor.
The ductwork system was designed and engineered to terminate with a high level, high velocity exhaust to mitigate any possible issues with neighbouring properties.
The whole system conformed to the DEFRA guide for commercial Kitchen Ventilation.
NOISE CONTROL
A noise report was commissioned to identify and employ the most appropriate and effective reduction methods – such as anti-vibration ductwork hangers and in-duct attenuators – to be factored in to the final specification.
ODOUR CONTROL
Working closely with our supply chain we designed an appropriate filtration and odour control system.
The installation incorporated baffle filters, electrostatic filters and an ozone injection system located in the internal plantroom close to the kitchen canopy.
This siting was chosen to best ensure that airborne grease and odour particulates were removed as close to source as possible, thereby allowing the full effect of the ozone treatment to be delivered and the majority of the duct to be kept relatively clean.
AIR-CONDITIONING
The restaurant is air conditioned by a Mitsubishi ‘split’ air-conditioning system. The fan coils are located within the restaurant and air is then ducted to the supply air grilles.
The fan coil ductwork was distributed through the existing castellated beams and the condensers were positioned at the rear of the building on a purpose-built gantry.
[Caswell are Mitsubishi Electric Business Solution Partners. See the ‘Products & Services’ section of this Case Study for more details and a link].
A tempered supply air system plus WC and general ventilation systems were also provided.
HVAC / BMS CONTROL
An HVAC control system was designed and installed to automatically operate all HVAC Services. The system comprised a main control panel and associated control power wiring.
FIRE RESISTING DUCTWORK
Caswell manufactured, installed and certified a short 10m section of CASWELL FIRESAFE® Fire Resisting Ductwork specifically to maintain fire compartmentalisation where the system needed to penetrate barriers within the landlord areas.
CASWELL FIRESAFE® is an internationally renowned Fire Resisting Ductwork range which encompasses both EN1366:Parts 1&8 and BS476:Part 24.
It is a critical Passive Fire Protection product and is manufactured under licence by Partners of our group company, Firesafe Fire Rated Ductwork Limited…including by our specialist division, Caswell FRD.
They both have a dedicated website, so you can explore what each have to offer in terms of advice, resources and practical involvement in any Fire Resisting Ductwork project…just by clicking the relevant logo.
[The sites will open in a new window, so you won’t lose your place here]



PERFORMANCE
This project demanded our usual technical and practical attention to detail coupled with a masterclass in HVAC system performance engineering; all within a constrained timescale. This was delivered.
PRESTIGE
This flagship restaurant for the Wagamama brand exuded all the attributes in keeping with its central location within Scotland’s capital city.
ENVIRONMENTAL
Every effort was employed to ensure that noise and odour control concerns were addressed and successfully resolved to deliver an environmentally-sound proposition.


Design • Manufacture • Installation • Commissioning & Certification
Caswell co-ordinated a whole host of HVAC-related products and services to enable the objectives and stated challenges to be met.
Here’s a list of the key elements with which we were involved:
Bespoke Caswell Commercial Kitchen canopy
Over-canopy access walkway with Chequer-plate floor
Kitchen Extract with high-level, high-velocity Stainless Steel discharge stack
Supply Fans
CASWELL FIRESAFE® Fire Resisting Ductwork system to BS476:Part 24
DW172 / DW142 BESA/HVAC specification fully-welded ductwork
In-duct Attenuators
Anti-Vibration ductwork hanger system
Odour Control measures including Baffle Filters, Electrostatic Filters and an Ozone Injection system
Mitsubishi* ‘split’ air-conditioning system including condensers, fan coils and supply air grilles
Tempered supply air system to Restaurant and WCs
HVAC BMS Control Panel
Commissioning
Click to view / download the PDF version

* Caswell are a Mitsubishi Electric Business Solutions Partner. Read more HERE